HOLLIS 1ST AND 2ND STAGES 200LX + DCX DIN

HOLLIS 1ST AND 2ND STAGES 200LX + DCX DIN

$749.95

Availability: Special Order

Part Number:240.2011.07.M Manufacturer: Hollis

HOLLIS 200LX + DCX DIN 1ST AND 2ND STAGES REGULAR

 

KEY FEATURES

  • Meets CE standard for cold water performance
  • Over balanced diaphragm 1st stage design
  • Nitrox compatible to 40% out of the box
  • Pneumatically balanced 2nd stage
  • Adjustable Venturi system

See More Product Details

 

About Hollis 200LX DCX Regulator

Hollis newest flagship first stage is the DCX and is coupled with the new 200LX Second Stage, design by divers for divers. Every feature is designed with high performance and superior manufacturing at every step. The DCX is surrounded by the most durable coating available today, PVD (Physical Vapor Deposition). The DCX was been redesigned to reduce weight while improving angle of LP and HP ports to maximize hoses routing. Hollis has made it an industry standard to include the 5th LP port making the DCX the diver's first choice for back-mounted doubles, side mount or even for the recreational diver that demands the same performance as a technical diver.

The DCX 1st Stage Regulator is an over-balanced diaphragm regulator design that provides progressively greater intermediate pressure as depth and gas density increases for superior gas delivery under the most extreme conditions. The diaphragm membrane transmits the pressure changes to the internal mechanism eliminating the need for the surrounding water to enter the intricate mechanism. The benefit of this type of first stage design is that none of the internal parts are exposed to contaminants such as salt, sand, chlorine or pool acids. These environmental contaminants cause corrosion and mineral deposits to form on the internal mechanism deteriorating regulator performance. The standard diaphragm regulator does allow water into the mainspring chamber so that the diaphragm can perform this transmission of pressure changes.

With the DCX there is a secondary environmental diaphragm membrane that seals off the spring chamber keeping the first stage completely sealed off from the environment adding a second layer of corrosion resistance and the environmental sealing prevents icing of the first stage, allowing the regulator to withstand the rigorous CE standard for cold-water performance.

Hollis newest flagship regulator is the 200LX Second Stage Regulator. The 200LX can be converted from a right-handed hose configuration to a left-handed hose configuration, in a manner of minutes. The valve of the 200LX is PVD" (Physical Vapor Deposition) Industrial Plated. PVD is a super-hard coating that is by far the most durable coating available today. Superior quality that will outlast any traditional plating. The Front stainless steel metal ring, inhalation knob dive/pre-dive end cap are also PVD" Plated. Second Stage Regulator is a pneumatically balanced PVD-plated brass valve results in smooth, easy breathing. Diver adjustable inhalation knob, allows diver to customize inhalation effort. The second stage has an adjustable Dive/Pre-Dive switch: Large Venturi lever has a soft rubber grip, which makes it easy to locate and use. Ergonomic exhaust channels bubbles away from field of view and reduces exhaust effort. All LX regulators come standard with 30" (76.2 cm) MiFlex hoses and orthodontic mouthpieces with dual color tabs. Regulator comes with a CD Owner's Manual.

This product can only be shipped to U.S. addresses.

 

Warranty Information

This product has a limited warranty of 24 months.

http://www.hollis.com/support/warranty/
 

510-729-5110

 

Hollis 200LX DCX Regulator Features

  • Hollis 200LX DCX Regulator:
  • Smooth, Easy Breathing
  • Adjustable Inhalation Knob, Allows Diver to Customize Inhalation Effort
  • Adjustable Venturi System (A.V.S.)
  • AVS: Simple Dive/Pre-Dive Switch Adjust Inhalation Effort
  • CD Owner's Manual
  • First Stage: Hollis DCX
  • Hollis Newest Flagship First Stage
  • DCX, Design by Divers for Divers
  • Every Feature Designed w/High Performance, Superior Manufacturing at Every Step
  • Physical Vapor Deposition (PVD) Finish
  • PVD: Most Durable Coating Available Today
  • Redesigned to Reduce Weight
  • Improving Angle of LP and HP Ports, Maximize Hoses Routing
  • Five 3/8" Threaded Low Pressure Port Design
  • 5th LP Port: 1'st Choice for Back-Mounted Doubles, Side Mount or Demanding Recreational Divers
  • Two 7/16" Threaded High Pressure Ports
  • Over-Balanced Diaphragm Regulator Design
  • Provides Progressively Greater Intermediate Pressure with Increased Depth and Gas Density
  • Superior Gas Delivery Under Most Extreme Conditions
  • Dual Diaphragm Design: Completely Seals Internal Components from Environment
  • Environmental Sealing Prevents Icing
  • Material: Forged Marine-Grade PVD Finished Brass
  • Nitrox Compatible to 40% Out-of-the-Box
  • Meets Rigorous CE Standard for Coldwater Performance
  • Second Stage Regulator: Hollis 200LX
  • Pneumatically Balanced Demand Valve Design
  • Physical Vapor Deposition (PVD) Finish Brass Valve
  • PVD: Most Durable Coating Available Today
  • Stainless Steel PVD Coated Cover Ring, Adjustment Knob & Pre-Dive/Diver End Cap
  • Smooth, Easy Breathing
  • Adjustable Inhalation Knob, Allows Diver to Customize Inhalation Effort
  • Adjustable Venturi System (A.V.S.)
  • AVS: Simple Dive/Pre-Dive Switch Adjust Inhalation Effort
  • AVS: Prevents Free-Flow During Shore Entries or Long Surface Swims
  • Lightweight ABS/Polycarbonate Housing
  • Patented Silicone Rubber Orthodontic Mouthpiece
  • Mouthpiece Provides Comfort and Reduced Jaw Fatigue

 

0 reviews for HOLLIS 1ST AND 2ND STAGES 200LX + DCX DIN

Write a review

Can't read? Reload
top